Choose language : English | Français                                                                                                                                       Choisir la langue : English | Français

Close
Open

Smart Energy Solutions

TRIAC SSR CONTROLLERS

Triac Solid State Relay Controllers

The solid state relay control is suitable for all processes, that have either long or short-timed cycles. However, the shorter the cycle time, the better is your control.

PRODUCT INFORMATION

Our solid state relay (SSR) is recommended for use with proportional temperature controllers and other applications where long life and solid state reliability are required. They provide ON-OFF control for any electrical resistance or HID lighting load.

TECHNOLOGY

The solid state relay control is suitable for all processes, that have either long or short-timed cycles. However, the shorter the cycle time, the better is your control.

ADVANTAGES

  • Modulates the power nearest to the demand and reduces energy costs and power consumption
  • Keeps the temperature closer to the desired set point for maximum comfort
  • Higher precision, superior than contactors
  • Fast adjustment and installation
  • Zero-crossing operation and silent arcless switching
  • Cycles once per second; very fast and quiet
  • No maintenance, due to less mechanical parts failure
  • Life expectation higher than 1 000 000 000 operations
  • Does not create RFI (radio frequency interference) and will not affect sensitive electronic equipment
  • Epoxy thermally protected, for humidity protection, overheat or contaminated environment protection

APPLICATIONS

  • Resistive loads such as commercial duct heaters
  • Lighting control
  • Electronic boilers
  • Electronic humidifiers
  • Industrial & commercial ovens and furnaces
  • Mine heaters
  • Integrated circuit processing equipment
  • Temperature control
  • Replacement of magnetic or mercury contactors

OPTIONS

  • NEMA-1 Enclosure
  • Temperature control
  • 3 legs power control
  • Semi-conductor fuses
  • 120 Vac control signal

SPECIFICATIONS

  • Accepts many input signals: 24 Vac, 3-32 Vdc (120-1 Vac on request)
  • Provides ON/OFF or pulse control for any electrical resistance or HID lights
  • Security factor of 2, i.e. 600 V surge protected and built for 1200 V
  • From 10 to 1000 A and a maximum of 600 V
  • 1 or 3-phase (on 3-phases applications, 3 legs cut-off is available)
  • Mounted on an aluminium heat sink
  • CSA US and cUL certified
  • The controller must be mounted in a ventilated area
  • 2-year exclusive warranty

SSR – Technical Data
CCS Model
Amps
Dimensions H” x W” x D” (without enclosure)
With Enclosure*
Quantity US Price
Spec sheet
CCT-06-1-S
6
3-1/32 x 2-5/8 x 7/8
N/A

82.00
CCT-15-1
15
2-1/8 x 4-3/4 x 2-5/8
A

49.00
CCT-15-1-C1
15
4 x 4-3/4 x 2-5/8
N/A

62.00
CCT-15-1-S
15
2-9/16 x 2-5/8 x 7/8
N/A

56.00
CCT-15-1-S-T
15
3-1/32 x 2-5/8 x 1-5/8
N/A

68.00
CCT-15-1-S-T240
15
3-1/32 x 2-5/8 x 1-5/8
N/A

100.00
CCT-15-3
15
6-1/2 x 4-3/4 x 2-5/8
A

197.00
CCT-15-3Y
15
8-1/2 x 4-3/4 x 2-5/8
A

297.00
CCT-25-1
25
2-1/8 x 4-3/4 x 2-5/8
A

58.00
CCT-25-1-C1
25
4 x 4-3/4 x 2-5/8
N/A

70.00
CCT-30-1
30
3-1/2 x 4-3/4 x 2-5/8
A

92.00
CCT-30-1-C2
30
4-11/16 x 4-3/4 x 2-5/8
N/A

100.00
CCT-30-3
30
6-1/2 x 4-3/4 x 2-5/8
A

218.00
CCT-30-3Y
30
8-1/2 x 4-3/4 x 2-5/8
A

322.00
CCT-40-1
40
6 x 4-3/4 x 2-5/8
A

213.00
CCT-40-3
40
8 x 4-3/4 x 2-5/8
A

353.00
CCT-40-3Y
40
10 x 4-3/4 x 2-5/8
A

493.00
CCT-45-1-C2
45
4-11/16 x 4-3/4 x 2-5/8
N/A

147.00
CCT-50-1
50
6 x 4-3/4 x 3
A

368.00
CCT-50-3
50
10 x 4-3/4 x 3
A

474.00
CCT-50-3Y
50
10-1/2 x 6-3/8 x 7-21/32
B

784.00
CCT-75-1
75
6 x 4-3/4 x 3
A

526.00
CCT-75-3
75
10 x 4-3/4 x 3
A

584.00
CCT-75-3Y
75
10-1/2 x 6-3/8 x 7-21/32
B

875.00
CCT-90-1
90
6 x 4-3/4 x 3
A

642.00
CCT-90-3
90
10 x 4-3/4 x 3
A

875.00
CCT-90-3Y
90
10-1/2 x 6-3/8 x 7-21/32
B

1312.00
CCT-135-1
135
7-1/2 x 6-3/8 x 7-21/32
B

757.00
CCT-135-3
135
7-1/2 x 6-3/8 x 7-21/32
B

983.00
CCT-135-3Y
135
12 x 6-3/8 x 7-21/32
E

1478.00
CCT-165-1
165
7-1/2 x 6-3/8 x 7-21/32
B

1014.00
CCT-165-3
165
12 x 6-3/8 x 7-21/32
C

1307.00
CCT-165-3Y
165
15 x 6-3/8 x 7-21/32
E

1906.00
CCT-200-1
200
7-1/2 x 6-3/8 x 7-21/32
B

1275.00
CCT-200-3
200
12 x 6-3/8 x 7-21/32
C

1748.00
CCT-200-3Y
200
15 x 6-3/8 x 7-21/32
E

2869.00
CCT-250-1
250
12 x 6-3/8 x 8-1/16
B

1452.00
CCT-250-3
250
15 x 6-3/8 x 8-1/16
C

2180.00
CCT-250-3Y
250
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

3269.00
CCT-300-1
250
12 x 6-3/8 x 8-1/16
C

1667.00
CCT-300-3
300
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

2451.00
CCT-300-3Y
300
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

3675.00
CCT-350-1
350
12 x 6-3/8 x 8-1/16
C

1884.00
CCT-350-3
350
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

2661.00
CCT-350-3Y
350
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

3994.00
CCT-400-1
400
15 x 6-3/8 x 9-1/2
C

2867.00
CCT-400-3
400
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

2867.00
CCT-400-3Y
400
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

4218.00
CCT-500-1
500
15 x 6-3/8 x 9-1/2
C

2267.00
CCT-500-3
500
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

3154.00
CCT-500-3Y
500
32 x 28-1/2 x 8-13/64
SEE DRAWINGS

4646.00
CCT-600-3
600
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
CCT-750-3
750
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
CCT-1000-3
1000
39 x 33 x 10-21/32
SEE DRAWINGS
C/F
* Enclosure Type A: 12 x 12 x 8 * Enclosure Type B: 16 x 12 x 12 * Enclosure Type C: 18 x 20 x 12 * Enclosure Type D: 5-1/2 x 9 x 4 * Enclosure Type E: 28 x 24 x 12-3/4 * C1: supplied with a 4″ x 4″ cover for installation onto a 4″ X 4″ electrical box. * C2: supplied with a 4-11/16″ X 4-11/16″ cover for a 4-11/16″ X 4-11/16″ electrical box.
Custom dimensions and Nema type enclosure on request

Consultez notre liste de prix ici : Liste de prix