TRIAC (SOLID STATE RELAY) CONTROLLERS
CCT Series
Triac (SSR) Controllers
Up to 750 Amp, 1 or 3 Phases
Approved by the State of Texas for Street Lighting Controls
Option: Over heat temperature sensor, and 120-1-60 or 240-1-60 control input
TECHNOLOGY
Cristal Controls Electronic Relay (SSR) is recommended for use with proportional temperature controllers and other applications where long life and solid state reliability are required. They provide ON-OFF control on any electrical resistance and HID lighting load.
The electronic relay control is suitable for all processes, either long or short-time constants. Consequently, the shorter the cycle time, the better is your control.
Applications
-
Resistive load such as commercial duct heaters
-
Lighting control
-
Electronic boilers
-
Electronic humidifiers
-
Industrial & commercial ovens and furnaces
-
Mine heaters
-
Integrated circuit processing equipment
-
Temperature control
-
Replace:
- Magnetic contactors
- Mercury contactors
-
Modulating the power nearest to the demand and reduces energy costs and power consumption.
-
Keeping the temperature closer to the desired set point for maximum comfort.
-
Higher precision, superior than with contactors.
-
Fast adjustment and installation.
-
Zero-crossing operation, eliminates the thermal shocks overshoot and undershoot.
-
Cycle once per second, very fast and quiet.
-
No maintenance, due to less mechanical parts failure.
-
Life expectation higher than 1 000 000 000 operations
-
Does not create RFI (radio frequency interference) and will not adversely affect sensitive electronic equipment.
-
Epoxy thermally protected, for humidity, protection, overheat or contaminated environment.
Specifications
-
Accept input signal: 24 VAC, 24 VDC, 3-32 VDC (120-1 Volts and 240-1 Volts on request) provides "ON/OFF" or "PULSE" control on any electrical resistance or "ON/OFF" on HID light road.
-
Security factory 2, I.E. 600 Volts surge protected and built for 1200 Volts.
-
From 10 to 750 Amps and a maximum of 600 Volts
-
1 or 3-phase (on 3 phases application 3 legs cut off is available)
- Available options:
3 legs power control
Semi conductor fuses
120-1 and 240-1 Volt external power supply
- Mounted on an aluminium heat sink and the electronic components are covered in a thermal epoxy.
- CSA and C US approved
-
2-year warranty.
Triac (SSR) - WITH COVER - 10 to 30 Amps |
 |
| Power Module |
Type Triac |
|
| Heat Sink |
Type MS-19921 |
| Voltage |
10 to 25A |
48 @ 347 VAC,
1 Phase |
| 30A |
48 @ 600 VAC,
1 or 3 Phases |
| Input Signal |
3-32 VDC, 24 VAC, 24 VDC - 6 mA per pole at 3 VDC. (For over 30 Amps 120-1 VAC ON REQUEST) |
|
| Triac must be mounted into a ventilated area |
Triac (SSR) - 10 to 90 Amps |
 |
| Power Module |
10 to 40A: |
Type Triac |
| 50 and 90A: |
Type Thyristors |
| Heat Sink |
10 to 15A |
Type MS-19921 |
| 25 to 90A |
Type MS-15170 |
| Voltage |
10 to 25A |
48 @ 347 VAC,
1 Phase |
| 30 to 90A |
48 @ 600 VAC,
1 or 3 Phases |
| Input Signal |
3-32 VDC, 24 VAC, 24 VDC - 6 mA per pole at 3 VDC. (For over 30 Amps 120-1 VAC ON REQUEST) |
|
| Modulating Control |
Yes |
|
| Zero-crossing |
Yes |
|
| Options |
Integral Overheat Protection - Fusing |
Triac (SSR) - 135 to 250 Amps |
 |
| Power Module |
Type Thyristors |
| Fan |
Type 150 cfm |
| Heat Sink |
No 62905 |
| Voltage |
10 to 25A |
48 @ 600 VAC,
1 or 3 Phases |
| Input Signal |
3-32 VDC, 24 VAC, 24 VDC - 6 mA per pole at 3 VDC. (120 VAC ON REQUEST) |
|
| Modulating Control |
Yes |
|
| Zero-crossing |
Yes |
|
| Options |
Integral Overheat Protection |
Triac (SSR) NEMA4 - 15 to 250 Amps |
Difference between TRIAC and TRIAC NEMA4
NEMA-4 TRIAC are designed so the heat sink is completely outside the enclosure and all the electronic controls are located inside the enclosure. |
| Power Module |
15 to 30A: |
Type Triac |
| 50 and 250A: |
Type Thyristors |
| Heat Sink |
15 to 30A |
Type MS-19921 and 66157-6 |
| 50 to 250A |
Type 66157 |
| Voltage |
15 AMPS |
48 @ 347 VAC,
1 Phase or
3 Phases |
| 30 to 250A |
48 @ 600 VAC,
1 or 3 Phases |
| Input Signal |
3-32 VDC, 24 VAC, 24 VDC (For over 30 Amps 120-1 VAC ON REQUEST) |
|
| Modulating Control |
Yes |
|
| Options |
Integral Overheat Protection - Fusing |
Triac (SSR) - Models and Dimensions |
| CCT Model |
Amps |
Dimensions L" x H" x W"
(without enclosure) |
With Enclosure* |
| CCT-10-1 |
10 |
2-1/8 x 1-3/8 x 3-3/4 |
D |
| CCT-10-1-C1 |
10 |
4 x 1-1/2.x 4 |
C1* |
| CCT-15-1 |
15 |
(6 ½) 2-1/8 x 2-5/8 x 4-3/4 |
D |
| CCT-15-1-C1 |
15 |
4 x 2-11/16 x 4-3/4 |
C1 |
| CCT-25-1 |
25 |
2-1/8 x 2-5/8 x 4-3/4 |
D |
| CCT-25-1-C1 |
25 |
4 x 2-11/16 x 4-3/4 |
C1* |
| CCT-30-1 |
30 |
3-1/2 x 2-5/8 x 4-3/4 |
D |
| CCT-30-3-C2 |
30 |
4-11/16 x 2-11/16 x 4-11/16 |
C2* |
| CCT-30-3 |
30 |
6-1/2 x 2-5/8 x 4-3/4 |
D |
| CCT-40-1 |
40 |
6 x 2-5/8 x 4-3/4 |
A |
| CCT-40-3 |
40 |
8 x 2-5/8 x 4-3/4 |
A |
| CCT-50-1 |
50 |
6 x 2-5/8 x 4-3/4 |
A |
| CCT-50-3 |
50 |
10 x 2-5/8 x 4-3/4 |
A |
| CCT-75-1 |
75 |
6 x 2-5/8 x 4-3/4 |
A |
| CCT-75-3 |
75 |
10 x 2-5/8 x 4-3/4 |
A |
| CCT-90-1 |
90 |
6 x 2-5/8 x 4-3/4 |
A |
| CCT-90-3 |
90 |
10 x 2-5/8 x 4-3/4 |
A |
| CCT-135-1 |
135 |
7-1/2 x 5-3/8 x 6-3/8 |
B |
| CCT-135-3 |
135 |
7-1/2 x 5-3/8 x -63/8 |
C |
| CCT-165-1 |
165 |
7-1/2 x 5-3/8 x 6-3/8 |
B |
| CCT-165-3 |
165 |
7-1/2 x 5-3/8 x 6-3/8 |
C |
| CCT-200-1 |
200 |
7-1/2 x 5-3/8 x 6-3/8 |
B |
| CCT-200-3 |
200 |
7-1/2 x 5-3/8 x 6-3/8 |
C |
| CCT-250-1 |
250 |
12 x 5-3/8 x 6-3/8 |
B |
| CCT-250-3 |
250 |
12 x 5-3/8 x 6-3/8 |
C |
|
* Enclosure Type A: 12 x 12 x 8
* Enclosure Type B: 16 x 12 x 12
* Enclosure Type C: 20 x 18 x 12
* Enclosure Type D: 9 x 5-1/2 x 4
* C1: supplied with a 4" x 4" cover for installation onto a 4" X 4" electrical box.
* C2: supplied with a 4-11/16" X 4-11/16" cover for a 4-11/16" X 4-11/16" electrical box. |
| Custom dimensions and Nema type enclosure on request |
|
|
|
|
|
© 2005-2006-2007 Cristal Controls Ltd
Products and specs are subject to
change without notice
|
|
Cristal Controls Ltd, 1375 rue Frank-Carrel, Suite 14
Quebec City, (Quebec) Canada G1N 2E7