Choose your country CANADA (FRANÇAIS) CANADA (ENGLISH) USA Home Site map
You are...
Building
Owner
Electrician
Contractor
Architect
Engineer
OEM

About Us Products Services Quotations Order Warranty Contact Us
Electrician-Contractor
 

Our SCRs

 

Triacs

  Step Controllers
  Lighting Control Systems
  Energy Management Systems
  Thermostats
  Download Center
  Contact us
 
 
 
You are Electrician-Contractor : Triacs
 

 

Cristal Controls’ Triacs are the ideal complement to heating systems. Indeed, when they control our ultraprecise thermostat to regulate a room or a zone’s temperature, they add a control function to traditionnal heating systems.

TRIAC (SOLID STATE RELAY) CONTROLLERS

CCT Series
Triac (SSR) Controllers

Up to 750 Amp, 1 or 3 Phases
Option: Overheat temperature sensor, and 120-1-60 control input

Technology

Cristal Controls’ electronic relay (SSR) is recommended for use with proportional temperature controllers and other applications where long life and solid state reliability are required. They provide ON-OFF control for any electrical resistance or HID lighting load.

The electronic relay control is suitable for all processes, that have either long or short-timed cycles. However, the shorter the cycle time, the better is your control.

Applications
  • Resistive loads such as commercial duct heaters
  • Lighting control
  • Electronic boilers
  • Electronic humidifiers
  • Industrial & commercial ovens and furnaces
  • Mine heaters
  • Integrated circuit processing equipment
  • Temperature control
  • Replacement of magnetic or mercury contactors

Advantages

  • Modulates the power nearest to the demand and reduces energy costs and power consumption
  • Keeps the temperature closer to the desired set point for maximum comfort
  • Higher precision, superior than contactors
  • Fast adjustment and installation
  • Zero-crossing operation and silent arcless switching
  • Cycles once per second; very fast and quiet
  • No maintenance, due to less mechanical parts failure
  • Life expectation higher than 1 000 000 000 operations
  • Does not create RFI (radio frequency interference) and will not affect sensitive electronic equipment
  • Epoxy thermally protected, for humidity protection, overheat or contaminated environment protection

Specifications

  • Accepts many input signals: 24 Vac, 24 Vdc, 3-32 Vdc (120-1 V and 240-1 V on request)
  • Provides ON/OFF or pulse control for any electrical resistance or HID street lights
  • Security factor of 2, i.e. 600 V surge protected and built for 1200 V
  • From 10 to 750 Amp and a maximum of 600 V
  • 1 or 3-phase (on 3-phases applications, 3 legs cut-off is available)
  • Mounted on an aluminium heat sink
  • CSA and C US certified
  • 2-year exclusive warranty

Available options

  • 3 legs power control
  • Semiconductor fuses
  • 120 Vac control signal

   SSR - with cover - 10 to 45 A

 
Power Module Built-in  
Heat Sink Type MS-19921
Voltage 10 to 25A 48 @ 347 Vac,
1 Phase
30A 48 @ 600 Vac,
1 or 3 Phases
Input Signal 3-32 Vdc, 24 Vac, 6 mA per pole at 3 Vdc. (For over 30 A : 120-1 Vac input signal available on request)  
Triac must be mounted into a ventilated area

   SSR - 10 to 90 A

Power Module 10 to 40A: Built-in
50 to 90A: External
Heat Sink 10 to 15A Type MS-19921
25 to 90A Type MS-15170
Voltage 10 to 25A 48 @ 347 Vac,
1 Phase
30 to 90A 48 @ 600 Vac,
1 or 3 Phases
Input Signal 3-32 Vdc, 24 Vac, 6 mA per pole at 3 Vdc. (For over 30 A : 120-1 Vac input signal available on request)  
Modulating Control Yes  
Zero-crossing Yes  
Options Integral Overheat Protection (MiEC-4)

   SSR - 135 to 250 A

 
  Download technical data

Power Module External
Fan Type 150 cfm
Heat Sink No 62905
Voltage 10 to 25A 48 @ 600 Vac,
1 or 3 Phases
Input Signal 3-32 Vdc, 24 Vac, 6 mA per pole at 3 Vdc. (For over 30 A : 120-1 Vac input signal available on request)  
Modulating Control Yes  
Zero-crossing Yes  
Options Integral Overheat Protection (MiEC-4)

  SSR NEMA-4 - 15 to 250 A

Difference between SSR and SSR NEMA-4
NEMA-4 TRIACs are designed so the heat sink is completely outside the enclosure and all the electronic controls are located inside the enclosure.
Power Module 15 to 30A: Built-in
50 to 250A: External
Heat Sink 15 to 30A Type MS-19921 and 66157-6
50 to 250A Type 66157
Voltage 15 A 48 @ 347 Vac,
1 Phase or
3 Phases
30 to 250A 48 @ 600 Vac,
1 or 3 Phases
Input Signal 3-32 Vdc, 24 Vac, 6 mA per pole at 3 Vdc. (For over 30 A : 120-1 Vac input signal available on request)  
Modulating Control Yes  
Options Integral Overheat Protection (MiEC-4)

   SSR - Models and Dimensions

CCT Model
Amps
Dimensions L" x H" x W"
(without enclosure)
With Enclosure*
CCT-10-1
10
2-1/8 x 1-3/8 x 3-3/4
D
CCT-10-1-C1
10
4 x 1-1/2.x 4
C1*
CCT-15-1
15
(6 ½) 2-1/8 x 2-5/8 x 4-3/4
D
CCT-15-1-C1
15
4 x 2-11/16 x 4-3/4
C1
CCT-25-1
25
2-1/8 x 2-5/8 x 4-3/4
D
CCT-25-1-C1
25
4 x 2-11/16 x 4-3/4
C1*
CCT-30-1
30
3-1/2 x 2-5/8 x 4-3/4
D
CCT-30-3-C2
30
4-11/16 x 2-11/16 x 4-11/16
C2*
CCT-30-3
30
6-1/2 x 2-5/8 x 4-3/4
D
CCT-40-1
40
6 x 2-5/8 x 4-3/4
A
CCT-40-3
40
8 x 2-5/8 x 4-3/4
A
CCT-50-1
50
6 x 2-5/8 x 4-3/4
A
CCT-50-3
50
10 x 2-5/8 x 4-3/4
A
CCT-75-1
75
6 x 2-5/8 x 4-3/4
A
CCT-75-3
75
10 x 2-5/8 x 4-3/4
A
CCT-90-1
90
6 x 2-5/8 x 4-3/4
A
CCT-90-3
90
10 x 2-5/8 x 4-3/4
A
CCT-135-1
135
7-1/2 x 5-3/8 x 6-3/8
B
CCT-135-3
135
7-1/2 x 5-3/8 x -63/8
C
CCT-165-1
165
7-1/2 x 5-3/8 x 6-3/8
B
CCT-165-3
165
7-1/2 x 5-3/8 x 6-3/8
C
CCT-200-1
200
7-1/2 x 5-3/8 x 6-3/8
B
CCT-200-3
200
7-1/2 x 5-3/8 x 6-3/8
C
CCT-250-1
250
12 x 5-3/8 x 6-3/8
B
CCT-250-3
250
12 x 5-3/8 x 6-3/8
C

* Enclosure Type A: 12 x 12 x 8
* Enclosure Type B: 16 x 12 x 12
* Enclosure Type C: 20 x 18 x 12
* Enclosure Type D: 9 x 5-1/2 x 4
* C1: supplied with a 4" x 4" cover for installation onto a 4" X 4" electrical box.
* C2: supplied with a 4-11/16" X 4-11/16" cover for a 4-11/16" X 4-11/16" electrical box.

Custom dimensions and Nema type enclosure on request
 

 

 

 
Links of interest © Cristal Controls Ltd - All Rights Reserved 1996 -